Drawing 1. Boiler room mechanical schematic and
layout specifications, including control and operation notes.
|
 |
Drawing 2.
Radiant manifold locations and tube layout for basement.
|
 |
Drawing 3. Radiant manifold locations and tube
layout for main floor.
|
 |
Drawing 4. Radiant manifold locations and tube
layout for second floor.
|
 |
Drawing 5. Distribution piping, manifold and
thermostat location for radiant system in basement.
|
 |
Drawing 6. Distribution piping, manifold and
thermostat location for radiant system on main floor.
|
 |
Drawing 7. Distribution piping, manifold and
thermostat location for radiant system on second floor.
|
 |
Drawing 8. Radiant system summary with
spacing, loop lengths, flow rate, delta T, head loss, velocity
etc.
|
 |
Drawing 9. Details for architectural and
mechanical interfaces.
|
 |
Drawing 10. Installation details for tube and
manifolds for
radiant walls; manifold piping details.
|
 |
Drawing 11. Installation, operation and
maintenance specifications.
|
 |
Drawing 12. Boiler room layout, ventilation
equipment and ventilation distribution ducting in the basement.
|
 |
Drawing 13. Ventilation equipment and ventilation
distribution ducting on the main floor.
|
 |
Drawing 14. Ventilation equipment and ventilation
distribution ducting on the second floor.
|
 |
Drawing 15. Ventilation system summary with air
flow rates, duct sizes, lengths, friction loss, velocity etc.
|
 |
Drawing 16. Equipment list, make, model, size and
power requirements. |
|
Professional Service Rates:
Indoor Climate Consulting Inc. rates are
in-line with professional engineering and technologist fees
based on a E3/C to E5/E and T3 to T7 classification as identified by The
Consulting Engineers of Alberta in the document tilted,
“Consulting Engineers Rate Guideline”.
Should you wish to discuss your project with us
please contact us first via
email and let us
know about your project and expectations.
Sincerely,
Robert Bean, R.E.T., P.L.(Eng.)
President, Indoor Climate Consultants Inc.
Director, www.healthyheating.com
Registered Engineering Technologist - Building construction (ASET
#8167)
Professional Licensee – Mechanical engineering (APEGA #105894)
Disclaimer/Terms of Use:
Indoor Climate
Consultants Inc. has prepared these illustrations and
specifications for internal use. The information contained
within reflects best judgment in light of the information
available at the time of preparation. Any use which a second or
third party makes of these documents, or any reliance on or
decisions to be made based on the documents, are the
responsibility of such parties. Indoor Climate Consultants
Inc. accepts no responsibility for damages, if any suffered
by individuals or firms as a result of decisions made or actions
taken based on these documents. These illustrations exclusively
owned by the original author, are strictly limited for the
purpose of illustrating the general layout, assembly and
installation of equipment for Radiant Based HVAC Systems for
residential structures and commercial building classifications A through E
and F3, non hazardous, non explosion proof, restricted to four
stories or less. These documents shall not be copied,
reproduced, or altered by any means or method, nor shall it be
distributed to any individual or companies without prior written
authorization from the original author. All drawings and
specifications are to be considered conceptual unless approved
for construction by Robert Bean, R.E.T., P.L. (Eng.) for the
specified client. Unless advised otherwise, any professional
stamp placed on these documents relates to the general layout
and assembly only.
|
For
additional support visit our
visitor services page.
|